• Home
  • Products
  • Two-Axis Digital RS485 Tilt Sensor
  • Two-Axis Digital RS485 Tilt Sensor
    ZCT245AL-485-BUS
    Two-Axis Digital RS485 Tilt Sensor
    GET A PRICE
    Description

    I. General Description

    ZCT245AL-485-BUS is a two-axis tilt sensor which developed and produced by Shanghai ZC sensor. Its measuring range is ±45 degree.It can communicate with PC via RS485.

     

    II. Features

    • Small size and light weight.

    • Be waterproof and dustproof, with aluminium shell.

    • Stable and reliable performance.

    • Anti-knock.

    • Cost effective and ease of integration.

    Support +5V or 7-15V power supply (note in order).

     

    III. Applications

    • Angle measuring, leveling adjustment, zero setting.

    • Mining machine and petroleum drilling equipment.

    • Aloft work platform monitoring.

    • Security control, monitoring, alarm system.

    • Angular measurement of arm, dam, construction, bridge.

    • Aligning control, bending control.

     

    IV. Technical SpecificationUnless otherwise specified, the following parameters were measured at room temperature 25°C)

    parameter

    Condition

    Min.

    Max.

    Unit

    Operating parameter

    Supply voltage

    7

    15

    VDC

    Quiescent  current

    25

    mA

    Working temperature

    40

    +85

    Performance parameter

    Measuring range

    Dual

    -45

    +45

    °

    Resolution

    °

    Accuracy

    RMS

    °

    Zero temperature drift

    -40+85℃

    °/℃

    Others

    Housing size

    mm

    Cable length

    m

     

    V. Data output format

    The device adopt serial communication way to output data.Output format: ASCII.

    1. RS485 communication protocol setting

      Baud rate: 9600bps, Start bit: 1bit, Data bit: 8bit, Stop bit: 1bit, Parity bit: None

    2. Angle output format:

    One set of data has 9 bytes.

    Byte10x2A

    Byte20x2B/0x2D

    Byte3Thousands digit of angle value(ASCII)

    Byte4Hundreds digit of angle value(ASCII)

    Byte5Tens digital of angle value(ASCII)

    Byte6Units digit of angle value(ASCII)

    Byte70x2E

    Byte8one digit after the decimal point of angle value.(ASCII)

    Byte90x0F

    If current angle value is 3.6 degree, it will display in HEX:

    2A 2B 30 30 30 33 2E 36 0F

    Notice: when out of measuring range, it will display

    2A 2B(2D) 30 38 38 38 2E 38 0F

     

    VI. User command(hex format):

    1. 0x1A 0x0C XX 0x0D ――setting the address of the sensor’s axes. Reurn 0x2A 0x0C XX 0x0F after successfully set.  XX means the address of the sensor’s x axes,its range from0×01 to 0×20 and defaulted value is 0×01. Y axis address is XX+0×01,Y axis defaulted address is 0×02, when X address is 0×20, Y axis address is 0×01.
    2. 0x1A 0x1C XX 0x0D ――setting the current angle as zero position. Return 0x2A 0x1C 0x0F aftr successfully set. XX means the address of the sensor’s axes,
    3. 0x1A 0x0E NN 0x0D――setting filtering rate.NN canbe set as 0×01(fastest)/0×02/0×03/0×04(slowest). There is no return value when successfully set and then the sensor comes into ready state.
    4. 0x1A 0x1E XX 0x0D――reading the inclination value. XX means the address of the sensor’s axes. Return value is the same as digital output.

     

    VII. Mounting size and attentions

    1. mounting size

    mounting size

    a. Connection definition (Customer provide)

    connection definition

    1

    Schirm / shield

    2

    7V~12V

    3

    GND (0 V)

    4

    RS-485 A

    5

    RS-485 B

    b. Connection definition (Default)

    RED

    7V~12V

    BLACK

    GND (0 V)

    BLUE

    RS-485 A

    YELLOW

    RS-485 B

    c. PCB SIZE and connection definition

    PCB-SIZE-and-connection-definition

    Connect definition

    ① ――― 7V12V

    ② ――― GND

    ③ ――― RS-485 A

    ④ ――― RS-485 B

    2. Installation attention

    Incorrect installment will lead to a big tolerance on the measured angle. Make sure the correct installation of ‘two planes’ and ‘two lines’,please pay attention to the following two points:

    ①: ‘two planes’ means mounting surface of the sensor should entirely be close to the mounting surface of the measured objects(the mounting surface of the measured objects should be horizontal as possible as it can). Angle is not allowed(eg: angle a in diagram A). Correct installation method refers to diagram B.

    ②:‘two lines’ means the axis line should parallel to the axis line of the measured objects. Angle is not allowed(eg: angle b in diagram C). Correct installation method refers to diagram D.

    inclinometer-Installation-attention

     

     

     

     

     

     

  • OEM & PRICE

    OEM, Lowest prices in the industry, MOQ as low as 1pcs.