    ZCT230M-LBS-BUS
    High Accuracy Inclinometer Dual Axis Digital Tilt Sensor
    P/N ZCT230M-LBS-BUS-3105
    Axis Dual axis
    Accuracy 0.05°
    Resolution 0.01°
    Power supply DC8~30Vol
    Total range +-30°
    Output 485 BUS
    IP Grade IP67
    GET A PRICE
    Description

    I. General Description

    ZCT230M-LBS-BUS is a 2-axis high accuracy inclinometer, which is reasearched and produced by Shanghai Zhichuan. RS485 output, including 485 communication protocol and supporting more inclination networking. Measuring range is ±30°, high resolution, adjustable response frequency and baud rate (2400-38400bps).

     

    II. Features

    Industrial devices entirely

    Stable and reliable performance

    Shockproof, anti-seismic

    High cost performance

    Housing protection: IP68

     

    III. Applications

    Construction machinery,construction vehicles

    Security control, tilt control

    Angle measurement, level adjustment, zero position adjustment

     

    IV. Technical Specification

    Parameter

    Test condition

    Min value

    Typical value

    Max value

    Unit

    Operating

    spec

    Supply voltage(1

    8

    24

    30

    V

    Quiescent current

    Supply is 24V

    15

    20

    mA

    Operating temperature

    -40

    85

    Performance

    spec

    Measuring range(2

    2-axis

    -30~30

    °

    resolution(3

    0.001

    °

    accuracy(4

    ±0.05

    °

    Zero temperature drift

    -40~+85℃

    0.5

    0.86

    °

    others

    Housing size

    72*72*45

    mm

    Cable length

    0.9

    1

    1.1

    m

    Remark 1: when the sensor work normally, make sure it is in the allowable range, 24V is introduced.

    Remark 2: the sensor should be installed horizontally.

    Remark 3: he smallest angular increment at which a detectable change in output can be measured.

    Remark 4: The maximum deviation of the output from the absolute input angle.

     

    Description of the communication commands:

    Frame format

    Description

    Start byte(1

    Address byte(2

    Packet length(3

    data(4.5.6.7….

    Cumulative check(N)

    HEX

    0xA1

    0×00-0x7F

    At least 4

    Checksum

    Protocol description    

    1. 0xA1 is starting code, not only the data from sub-computer to host computer but also data from host computer to sub-computer, are coded starting from 0xA1;
    2. 0xAF is the reserved address, there is up to one reserved address in the bus. 0×00 is the broadcast address of the host computer. All the sub-instruments will response to the reserved address. The common command used the address is setting the baud rate of bus instruments;
    3. Packet length, from this byte(not contain this byte), data byte, cumulative check, to end byte(not contain calculation byte and parity), maximum length is 255 bytes;
    4. ①—-sender’s address code, 0xAF means host computer sends. Other HEX means the address of the instruments which send the data(using for communication between two sub-instruments), using sender’s address to fill the byte;
    5. ②—-frame type, 0×00 means command frame, 0×01 means data frame;
    6. ③—-MSB of the command word;
    7. ④—-LSB of the command word;

    N: Cumulative check and parity, sum from the address byte behind the packet to the byte before cumulative sum, then the 8 lower bits is the cumulative check.

  • OEM & PRICE

    OEM, Lowest prices in the industry, MOQ as low as 1pcs.