    ZCT1XXK-LMS-64
    High Precision 1-Axis Analog Inclinometer Tilt Sensor
    P/N ZCT1XXK-LMS-64
    Axis Single axis
    Non-linearity 0.2 %/FS
    Resolution 0.01°
    Power supply DC9~32Vol
    Total range Variety
    Output 0V~5V Voltage
    IP Grade IP65
    GET A PRICE
    Description

    Technical specificationroom environment 25℃

    Parameter

    Test condition

    Min.

    Typ.

    Max.

    Unit

    Electronic specification

    Supply voltage①

    9

    32

    V(DC

    Quiescent current

    When supply is 24V

    30

    40

    mA

    Operating temperature

    -40

    85

    Performance specification

    Measuring range②

    ZCT100K-LMS-64

    0

    90

    °

    ZCT1C0K-LMS-64

    -15

    105

    °

    ZCT1F0K-LMS-64

    -90

    100

    °

    ZCT1K0K-LMS-64

    -90

    90

    °

    ZCT1360K-LMS-64

    0

    360

    °

    Resolution

    0.01

    °

    Non-linearity③

    ±0.2

    %/FS

    Sensitivity

    ZCT100K-LMS-64

    55.56

    mV/°

    ZCT1C0K-LMS-64

    41.70

    mV/°

    ZCT1F0K-LMS-64

    26.30

    mV /°

    ZCT1K0K-LMS-64

    27.80

    mV /°

    ZCT1360K-LMS-64

    13.90

    mV /°

    Zero temperature drift

    -40+85℃

    ±0.008

    °/℃

    ±0.86

    °

    Load resistance

    VCC=24V

    600

    Ω

    others

    Size

    84*55*37

    mm

    Cable length④

    5.9

    6

    6.1

    m

    Remark:
    ① In normal operation state, make sure the supply voltage is in the allowable range, and 24Vol is introduced.
    ② The inclinometer should be installed vertically.
    ③ Non-linearity means the deviation between output curve and the best fitting line in the measuring range.
    ④ Default cable length is 6m. Please let us know if you need other length.

    Size (unit: mm

    Size

    Wire connection

    Red: Power VCD         Black: Power GND         Yellow: Vout         Blue: NC

    Ⅷ. Installation and connection diagram

    About mount methods, please refer to the following. If the mount surface or the running surface slops, there will be an error for the measuring results.

    Installation and connection diagram-02

    Order information: ( Please add the cable length,default is 6m)

    ZCT100K-LMS-64 measuring range 0~90 deg;
    ZCT1C0K-LMS-64 measuring range -15~105 deg;
    ZCT1K0K-LMS-64 measuring range -90~90 deg;
    ZCT1F0K-LMS-64 measuring range -90~100 deg;
    ZCT1360K-LMS-64 measuring range 0~360 deg;

  • OEM & PRICE

    OEM, Lowest prices in the industry, MOQ as low as 1pcs.

  • TEAM

    Our professional R&D and service engineers can find for you solutions that best suit your application.

  • ON TIME

    Efficient and effective production management, timely follow-up and reassured lead time.

  • QUALITY

    One year warranty, long-time stability and reliability, 100% QC passed before delivery.

  • Top